Product news

news featured image

NEWS

Cam Switches Ex9ZE

  • Meet requirements of IEC / EN 60947-3 and IEC / EN 60947-5-1
  • Cam Switches are used in main and auxiliary circuits requiring frequent switching on-off:
  • In switching on-off of single, two and three-phase electric circuits
  • In controlling of devices measuring voltage-current values
  • In processes of starting or stopping by switching on or off the supply circuits of motors
  • As on-off switch, selector and step-alternator in transformers and welding machines
  • As pole-alternator or grouping switch, in required places such as network-regulator
  • As automatic, reversible switch with start
  • Rated current 10 A up to 160 A
  • Utilization Category AC-3, AC-4, AC-23
  • Protection rating IP20 (Body/Poles)
  • IP40 (From panel door installation)

Our cam switches are manufactured according to the highest engineering standards by benefiting from the modern technological developments in the range of switch devices by using the highest-quality isolation materials and silver compound riveted copper contact. Each switch consists of various on-off elements that can be easily assembled-disassembled according to the switching program. The casing of the switching on-off elements is made of plastic material resistant to electric leakage and arc effects. The body material is PBT which can resist and is non-flammable up to very high temperatures. Contact materials and terminals fully comply with EN 60947-3.

news
DC Coil Contactors – Ex9CS + Ex9CD

  • Contactors according to IEC / EN 60947-4-1
  • Four frame sizes with rated current up to 100 A at 400 V AC-3
  • 3-pole versions
  • Coil control voltage 24 — 220 V DC -Rated conditional short circuit current Iq = 50 kA
  • suitable mainly for industrial applications, can be used also for domestic ones
  • Mounting onto device rail (DIN) 35 or 75 mm (frame sizes 65 and 100) or onto panel

Ex9CD (DC) coil contactors are electromagnetic devices used to control the switching on and off, of electrical circuits in applications where direct current is utilized. They are essential in systems where reliability and energy efficiency are critical Ex9CD control contactors are intended for various applications including heavy industrial ones. Splitting into four frame sizes brings optimization of electrical parameters and mechanical dimensions. All these frame sizes share accessory auxiliary contacts. Overload relays Ex9R differ with the frame sizes in order to fit respective contactor of given rated current. Frame size 18 contains contactors with rated currents AC-3 9, 12 and 18 A at 400 V. Size 38 consists of rated currents 25, 32 A. Version 65 is split into currents 40, 50 and 65 A. Finally frame size 100 is covered with rated currents 80 and 100 A.

news
4P Contactors Ex9C up to 100 A

  • Contactors according to IEC / EN 60947-4-1
  • Four frame sizes with rated current up to 100 A at 400 V AC-3
  • 4-pole versions
  • Coil control voltage 24 — 415 V AC
  • Rated conditional short circuit current Iq = 50 kA
  • Suitable mainly for industrial applications, can be used also for domestic ones
  • Mounting onto device rail (DIN) 35 or 75 mm (frame sizes 65 and 100) or onto panel

Ex9C contactors are intended for various applications including heavy industrial ones. Splitting into four frame sizes brings optimization of electrical parameters and mechanical dimensions. All these frame sizes share accessory auxiliary contacts. Overload relays Ex9R differ with the frame sizes in order to fit respective contactor of given rated current. Frame size 18 contains contactors with rated currents AC-3 9, 12 and 18 A at 400 V. Size 38 consists of rated currents 25, 32, 38 A. Version 65 is split into currents 40, 50 and 65 A. Finally frame size 100 is covered with rated currents 80 and 100 A.

news
Silent installation contactors Ex9CHH

  • Silent installation contactors with AC/DC control voltage Ex9CHH
  • Meet requirements of IEC/EN 61095 IEC/EN 60947-4-1, IEC/EN 60947-5-1
  • Rated current up to 16, 20, 25, 32, 40, 63 A
  • Control coil voltage 12, 24, 48, 110, 230 V
  • AC/DC control coil voltage
  • Rated frequency 50/60 Hz
  • 1 up to 4-contact versions
  • Hum free (silent)
  • Various contact combinations

The Ex9CHH installation contactors are designed for use in household and building modular distribution boards. These contactors are primarily utilized in building automation systems for the switching and control of lighting, heating systems, ventilation, pumps, heat pumps, and other applications. The silent operation of these contactors makes them particularly well-suited for environments where noise reduction is critical, such as offices and residential settings. Additionally, their AC/DC control voltage capabilities meet higher technical demands, ensuring dependable operation in more demanding scenarios. Optical indicator on the front side indicates status of the contacts and voltage on control coil. The contactor provides the option to add an auxiliary contact AX-CHH as an accessory.

news
Accessories for Ex9CHH a Ex9CHM

  • Accessories for installation contactors
  • According to IEC / EN 60947-5-1
  • Auxiliary contacts for installation contactors with manual operation Ex9CHM
  • Auxiliary contacts for silent installation contactors Ex9CHH
  • 1 NO + 1 NC or 2 NO version

Auxiliary contacts AX-CHM are designed for installation contactors with manual operation Ex9CHM and Auxiliary contacts AX-CHH are designed for silent installation contactors Ex9CHH. Units are mounted from the right to the installation contactors. Contact units are equipped with 1 NO + 1 NC or 2 NO combination of contacts.

news
Power supplies - Ex9PS2

  • Power range from 15 W up to 92 W
  • Rated output voltage 12 V DC or 24 V DC
  • Integrated internal protections
  • Low ripple and noise
  • Efficiency up to 90%
  • Fine adjustment of the output voltage

DIN-rail mounted power supplies Ex9PS2 provide a convenient solution for powering DC operated devices like bells, videophones, vending machines, security systems, etc. Since these power supplies are air convection cooled, no cooling fans are needed. Rated output voltage 12 or 24V DC with power range from 15 up to 92 W. Adjustable output voltage allows customization to specific application requirements, such as compensating for voltage drop due to line length.

news
Wi-Fi Digital Time Switches Ex9DTSW

  • Wi-Fi Digital Time Switches
  • Rated operational voltage 24 - 240 V AC/DC
  • Daily, weekly, yearly and astronomical switching programs
  • Simple setting after the first start-up
  • Possibility of permanent connection to the local network
  • Time synchronization through NTP server
  • Standard (2MU) width versions
  • Replaceable battery to back up the set time
  • The astronomical program has a selection of more than 500 preset cities

Installation digital time switch with Wi-Fi connection is designed for precise time control in various residential, commercial, and industrial applications. These multifunctional switches offer daily, weekly, yearly, and astro¬nomical programs. They feature a user-friendly interface, including a backlit LCD display, and can be controlled and programmed via a built-in web server using a Wi-Fi connection. The Ex9DTSW also supports time synchronization through an NTP server, ensuring accurate timekeeping. With options for one or two channels, pulse/cycle output mode, and advanced features like astro program integration (which includes a selection of over 500 preset cities), the Ex9DTSW series allows for highly customizable and energy-efficient operation. The device also includes a battery backup to maintain time settings during power outages and supports automatic summer / wintertime transitions.

news
Light intensity switches - Ex9LDS2

  • Rated operating voltage 230 V AC
  • Analogue and digital version
  • Without and with integrated time switch
  • Random switching mode (Ex9LDS2)
  • Adjustable light sensitivity up to 50 000 lx
  • External brightness sensor with IP65 rating

Light Intensity Switches Ex9LAS and Ex9LDS2 are used for light switching according to actual daylight intensity (Ex9LDS2 device also according to time), so the light fixtures are switched only if necessary and it can save money for consumed energy. This switch can automatically change between summer and wintertime. It operates in daily, weekly or yearly switching program and can be connect to light control systems with other devices. External brightness sensor is included in the scope of delivery.

news

EXTENSION

Ex9M AC Magnetic protection – Moulded case circuit breakers

  • Electromagnetic tripping unit for motor protection
  • Frame sizes M1-M5
  • Rated operating current up to 800 A
  • 3 and 4-pole versions
  • Rated ultimate short circuit breaking capacity Icu= Ics up to 150 kA,
  • Rated voltage 415 / 690 V AC

Moulded Case Circuit Breakers Ex9M Magnetic (M) type are intended for applications in motor protection mainly. Testing according to IEC / EN 60947-2 standards ensures the functionality and reliability for wide variety of applications including isolation. These breakers are offered with breaking capacities from 36 kA up to extreme 150 kA. High rated impulse with stand voltage makes it possible to use them even in system with occurrences of transient overvoltage waves of high intensity, e.g. in heavy industry. Utilization category A circuit breakers.

news
Moulded case circuit breakers Ex9M6 SU20S

  • LCD display version
  • SU20S Standard type smart unit controller
  • Frame sizes M2-M6
  • Rated operating current up to 1600 A
  • 3 and 4-pole versions
  • Rated ultimate short circuit breaking capacity Icu=Ics up to 150 kA,
  • Rated voltage 415 / 690 V AC
  • High tripping accuracy, reliable operation, less sensibility to ambient temperature

Moulded Case Circuit Breakers Ex9M with SU20S type of smart unit are intended for applications in power distribution mainly. Testing according to IEC / EN 60947-2 standards ensures the functionality and reliability for wide variety of applications including isolation. The electronic controller with LCD display allows a detailed and accurate commission of the device for the installation requirements. Electronic technology improves the stability of the device on applications with significative mechanical stress. These breakers are offered with breaking capacities from 36 kA up to extreme 150 kA. Rated impulse withstand voltage Uimp up to 12 kV makes it possible to use them even in system with occurrences of transient overvoltage waves of high intensity, e.g. in heavy industry. Utilization category A and B circuit breakers.

news
Ex9M6SD MOD version - AC Switch disconnectors

  • AC MCCB Switch Disconnectors
  • Rated operating current up to 1 600 A
  • Tested according to IEC / EN 60947-3
  • AC current character
  • 2, 3 and 4-pole versions
  • Rated operating voltage Ue up to 690 V AC

AC versions of MCCB based Switch Disconnectors Ex9MSD are used as a main switch in many various circuits. They are intended primarily for applications in power distribution. Testing according to IEC / EN 60947-3 standard ensures functions and reliability for wide variety of applications. These switch disconnectors follow the same design pattern than their circuit breaker equivalents. Therefore there is possibility to use the fully compatible range of external and internal accessories including extended rotary handles, auxiliary contacts, tripping units and many others.

news
BAB22 – battery box

  • Battery box for smart unit ‘s power supply
  • Applicable to the SU20S electronic type moulded case circuit breaker
  • Suitable for circuit breakers of frame sizes from M2 to M6

news
COM22 – communication module

  • Operating voltage 230 V AC and 24 V DC
  • Communication protocol through Modbus
  • Auxiliary component of moulded case circuit breakers used for networking and communication of MCCBs to facilitate remote control for users

news
Group Change-over switches Ex9BT3G

  • Group Change-Over Switches
  • Meet requirements of IEC / EN 60947-3
  • Rated current from 16 A to 63 A
  • Rated operating voltage 240/415 V AC
  • Utilization category AC-22A
  • Contact form (I-O-II)
  • 1 up to 4-pole versions
  • Rated frequency 50/60 Hz

Group Change-Over Switches Ex9BT3G are designed and intended for switching of auxiliary, control, mea¬suring and switching networks. Testing according to 60947-3 standard ensure functions and reliability for wide variety of applications. Utilization category AC-22A allows switching under load. They are available in variants with change-over contacts (CO) from 1 CO up to 4 CO. Contact form (I-O-II) allows a load to be manually changed from one electrical source to another, without risk of short-circuit.

news
Ex9M6 MOD 24V DC SU20L

  • 3 and 4-pole Electronic Moulded Case Circuit Breakers
  • Ics = Icu = 50 kA at 415 V AC
  • Ir can be set in steps (0.4-0.5-0.6-0.7-0.8-0.9-0.95-1.0) × In
  • Ii can be set in steps (2-3-4-6-8-10-12) × In
  • Mounting screws and phase barriers in the scope of delivery
  • 2x AX, 1x AL, 1x SHT26, 1x XF26 with same operative voltage are pre-mounted (customizable under request)

Ex9M Moulded Case Circuit Breakers with SU20L smart units are designed for power distribution, offering reliability and isolation per IEC / EN 60947-2 standards. The DIP-switch electronic controller enables quick setup, ensuring stability under mechanical stress. These breakers provide breaking capacities from 36 kA to 150 kA and withstand impulse voltages up to 12 kV, making them suitable for heavy industry. They are available in utilization categories A and B.

news
Ex9M6 MOD 24V DC SD

  • DC MCCB Switch Disconnectors
  • Frame sizes M1-M6
  • Rated operating current up to 1600 A
  • Tested according to EN 60947-3
  • DC current character
  • 2, 3 and 4-pole versions
  • Rated voltage 500 V DC (2-pole), 750 V DC (3-pole) and 1000 V DC (4-pole) for Ex9M1SD to Ex9M5SD
  • Rated voltage 750 V DC (3-pole) and 1500 V DC (4-pole) for Ex9M6SD

DC versions of MCCB based Switch Disconnectors Ex9MSD are used as a main switch in DC applications, such as PV installations. Testing according to IEC / EN 60947-3 standards ensures functions and reliability for wide variety of applications. These switch disconnectors follow the same design pattern than their circuit breaker equivalents. Therefore, there is possibility to use the fully compatible range of external and internal accessories including extended rotary handles, auxiliary contacts, tripping units and many others.

news